The post-purge cycle will be completed once the blower prover switch closes. Please note: The majority of our literature and brochures are in English only. You need to use a K-1766 salt test kit or a calibrated meter. At the end of last season we noticed a leak. Everything coming in appears to be tight. External bypass is out of adjustment. Any insight? Probably not cant think of another issue. 1. check that the pump impeller and shaft are spinning freely. Hi Don, if you have four suction lines coming into the pump, that would be skimmer, skimmer, main drain and spa drain? the termistor was blown.
Blue Essence Replacement Salt Chlorinators and Salt Cells The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. Tried to vacuum. 3200 ppm is the ideal level. Recently I started getting a loud vibration hum from my hayward pump. All breakers have some wiggle to them usually, but a very loose breaker could be a hazard for arcing or even fire so should be checked out, if so. My pump motor does not start until I spin the shaft then it runs for about 15 min and shuts off and I can hear the motor humming and it feels very hot to the touch. 240v Input voltage is present. Got pump from a friend and he had no problems. You can experiment with pump RPM settings, to exceed the threshold. Hi Davy! Otherwise if not, you go in thru the back of the motor, remove the capacitor bracket to drop the cap out of the way, so you can slip a 7/16 wrench on the slotted back 1/2 of the shaft, and work it back and forth for 30 seconds to break the rust. The LED light should go out. Profile, Create a Pool Owner On the Swim Pro filters, check the two lock nuts under the lid, which secure the pressure gauge and air assembly, and be sure the filter is seated firmly into the base. After installing the new pump, priming it, it started running as normal, after a short time the new pump shut down and was very hot. Air can also enter through split vac hoses, but since yours is new Third problem could be if the new pump moves much more water than the old pump (not all horsepower pumps are the same 2 different pumps of the same hp, can produce vastly different flow rates. there is an air leak, on the pump lid, or around the pipe that comes into the pump, or the pump drain plug. the loosed its prime again. New gauge was ordered. On an Intermatic timer clock, there is a tab, at around 4 oclock on the dial, that is pushed to the left to turn off the timer, or override the timer settings. If you havent inspected your cell yet, now is aperfect time. I took apart the impeller and didnt see anything that could cause a problem. In some instances, it could just be a bad breaker. If any of these readings are outside limits, replace motor. This usually means the motor needs to be replaced. Likewise, it could be any other obstruction after the pump (partially clogged pipes, small pipe size, partially closed return valves) all of which will produce higher than normal filter pressure. 4 New pump 2 years old. If it clogs up again, you will need to break it down and manual clean, then soak in DE Filter Cleaner not so hard and the best cleaning, just a lot of little nuts and washers to remove and replace. of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the dr myers ultrasound. Do you have any ideas?? So I inspected the wiring into the electrical panel. Any ideas as to how to fix this? Harwil type flow switches can become damaged over time and will need replacement at some point. I purchased a hayward powerflo matrix 1.5 pump and Proseries 21 Filter a week and a half ago. The temperature of the pool water is too high or too low to operate. Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. I removed it and put the old pump back (20 years old), it works and does not shut down. fingers crossed, as we say. Hi Sean, the Powerflo pump lid has a very tight seal, likely the o-ring needs to be removed, cleaned off with a rag, replaced and lubed with a Teflon lubricant like Magic lube or other Pool Lube. Dont feel that resistance when bumping. I have this same Drive Error Message. Check that the shaft spins properly, and recheck all wiring. Let it sit overnight . Is the shaft spinning freely? Pump shutoff during 24 hours of pouring rain. Should have the hard plastic side facing the motor and the soft rubber side facing the impeller. And since it was running before (it shut off), its probably not rust. Check that the timer clock motor is working. Higher horsepower motors are usually only 230V, above 2 hp, but lower hp motors are sometimes reversible, or have the ability to wire either with 110V or 220V, but they will say this on the motor label if they are (reversible) and have a diagram also. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | We would like to show you a description here but the site wont allow us. Could the filter be plumbed backwards possibly? For Drive Error Pump is Stalled error message, the first thing to check (as you did already) is that the motor shaft spins freely, and the impeller is not clogged. It worked great last year, and when i went to program it this year, it didnt work unless I switch it on and off manually. I have a S-210 Hayward pool pump and it started spitting sand so I bought a Folding Umbrella Lateral Holder AssY when I dumped the sand out I think 2 of them were broken for a couple of months it seems sand has been dumping in the pool thats why I bought the lateral. First eliminate water flow issues, then gas flow issues, and finally the low voltage electric currents that run between pool heater components. If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. Thanks, Hi Nancy, this is a common problem water leaking out of the backwash line, while filtering. Thanks. 1. I will also say that a truly drip-proof pool system is not really the norm, most filter systems with a few years on it will ooze and drip here and there, and most often its of little concern. Or do I have a friction issue in the impeller? As to the filter, pool filters need to be matched to the flow rate of the pump. Also make sure that the stationary switch copper tabs are not fused together, and that it is centered on the centrifugal switch. Set the test meter to Ohms, of 1K or higher. The water level in the pool is high enough, but Im getting a whirlpool in the skimmer basket, and the water returning back into the pool is so powerful, its creating a whirlpool and air bubbles I dont know what else to do? Hi Paul, Ants can be a problem, when they get around motors or circuit boards, but it sounds like a pump motor problem, and could simply be a weak capacitor, in the rear of the motor (black cylinder). I put a new 1 hp motor on the pump, and new mechanical seal in the pump, problem still the same. For a better experience, please enable JavaScript in your browser before proceeding. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. Now there is no water running from the pool to the motor basket. Now it runs nice and quiet but still overheats and shuts off. Scoop out debris left in basket area, and try again. Anything else to fiddle with or bad motor? If clogged, open the pump up, and ream out the impeller vanes with a flexible wire. Could possibly be loose wires on the motor or timer, possibly a loose centrifugal switch or stationary switch on the motor, or maybe the windings in the motor are shorting out. When we turned it on heard a pop and blew fuse. Clean Gasket (no bits of debris or de powder), 2. The pump will draw air in if it can it is easier than pumping water, or the path of least resistance. Spray shaving cream around all of these areas and run pump with the vac connected, to see if you can see the cream being sucked in, in these areas. We tried opening the pool today when we plugged in the Hayward filter it keeps blowing the circuit breaker. I would turn it off and it would hum and eventually start. What am I doing wrong?? If the pump makes no noise at all, turn on power, and with a multi meter, check the power at the pump, switch/timer and breaker, the problem lies where the power dies. Tried to backwash. Is there a trick to this? I have a Heyward VS 500 that suddenly started making a sound like a poker card stuck in your spokes of your bike at all speeds. Hi Jim, check the wire connections, and the voltage coming into the motor. Attach a bond wire to the Eco star drive pump or tighten the loose screws on the bottom of the motor. If the motor shaft wont turn, you can work it loose by spinning the shaft with pliers on the front end of the shaft, or a 7/16 wrench on the back end of the shaft. What and how should I go about diagnosing this? You can plug the pump into a long extension cord and test it with another outlet on the house, to rule out problems with the outlet its plugged into now. Hi Pat, yes they should be plug and play, was the cord attached already, or did you install? Start here Step 1: Select your pool type. It feels like its not doing what its supposed to do. JUst installed new heyward pump . When it stops again, you may want to pull off the filter valve from the filter, and inspect the top few inches of sand, maybe replacing it with new. https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS the sound may possibly be a problem with the internal bypass, located in the front header. I just want to clarify..we had a problem with the fuse box and its just been changed. If they are within range, replace the drive. when i reassemble after cleaning, pump works great for about 5 mins even at 30 psi. Hi there, 30 psi is pretty high pressure, sounds like the pump is having trouble pushing thru are you using enough DE powder? Hi you are getting power inside the motor, on the terminal board? Seemed to be operating fine and I was vacuuming pool and lost suction. Automatic reset is 60 minutes. If assumed to be the capacitor, get the MFD number printed on it, and find an exact replacement capacitor on our site, or from a local electric motor shop. I remplace it and now the sistem works!! There is also a leak somewhere in the system because there is water on the pad. Hello, my motor runs for 20 seconds then stops. "
Point the capacitor away from you and others, while discharging. Check the switches in the back of the motor, the centrifugal on the end of the shaft, and the stationary, mounted at 6 oclock, to look for any loose screws or insects, or mis-alignment. If it reoccurs, you may have some pipe problems, such as a collapsed flexible PVC pipe on the skimmer. Profile, Create a Pool Mine is doing same thing. Do I need to prime it? 7. If i knew what make/model of pump you have, I could be more specific. I needed to rotate the housing pump but for some reason the screws dont seem to b lined up. It actually burned up shortly after my arrival and troubleshooting it. This year, I noticed at times that the flow rate on low speed is less than it was last year. With a flashlight (and your glasses), you can also look into the Visual Motor Check hole in the top of the mechanism, you should see gears moving. Thanks. Start up again with a fresh (Full) charge of DE powder. Have a Hayward 1HP self priming super pump on an older pool the motor bearings are screaming. If thats not the problem, try soaking the fingers again, with a stronger solution, and/or leaving them soaking longer. Hi Davy, Whenever Ive seen that its from too much voltage, like connecting 220V to a motor wired for 110V.
Hayward Global To remedy this, simply open up your pump, and clean out any rubbish. If there is an external 2-speed timeclock, check the wiring, esp. What does F5 mean? We cant figure put how to get the pump going they have a circuit box outside its hooked to but it seems its not working. All the hoses have new Teflon tape and they are secured. The pump then ran fine for about 10 minutes and then stopped working again. Pump making loud grinding noise, any solutions. Third, is there a valve closed after the filter, or some other obstruction? Hi Jeanna, most of those slide from 230 to 115, but some do have to be unplugged and replugged. I put the pump back together and it still leaks. It could have also overheated, when this happens, it will work again after cooling down. Any ideas as to what could be the problem? I made sure the basket was seated properly and put grease on the o-ring on the cover and made sure it was tight. Getting air in basket, changed gasket with lube still have the same issue. Hi, yes shaft seal failure. We have a hayward pump and heater. Hayward has a 4 year warranty on these drives. Thoughts? Shut down the power to the pump from the breaker for 15 minutes turn back on and try to run the pump. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). The o-ring should be a very tight fit also, not loose in the groove of the lid. It looks like its coming from in between the motor and pump.Am I correct in thinking I need a new seal plate kit? Any suggestions?? I added new wire and plug end but when I plug it in it trips the breaker. If so, you can replace just the motor, or the entire pump. Checked circuit breakers inside and out and checked to make sure power is getting to pump. It is not just the connection that is leaking, the pump body itself has sprung at least one leak near the neck of the top fitting. outlet still on. Hi, I just had an electrician install a Hayward Super II Energy Efficient Pump 3/4 HP SP3007EECA. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. If the blower prover switch does not close after the blower starts the control will stop the ignition trial go into lockout. On attempting to open the pool, the motor started humming. This one is 5 years old. I cant imagine paying someone to take 2 bolts off. Hi Jim, as I like to say, the problem lies, where the power dies. Took it to pool mart and they cleaned it out and said everything was fine inside it. After 15-20 minutes, after cooling, the switch will close again, and the motor should restart. We opened our pool a week ago and havent had a problem until today (May 23. Any tips on getting the cover off to get to the capacitor (after removing the two screws)? Do I need to use lube on the gasket, how much sand should be in the filter? I checked the pump and is is very hot. My client thinks the motor was 1hp, but he really not sure. Chapter 1: The Evil Emperor's Son. That is usually the capacitor, a black cylinder in the back of the motor. They can also fail if used on a salt pool (there are salt seals that can be used), or if the motor and shaft heats up to high temps. BLUE WORKS PCB Main Circuit Board Compatible with Hayward Goldline GLX-PCB-Main System Board Visit the BLUE WORKS Store 193 ratings $16999 FREE Returns Available at a lower price from other sellers that may not offer free Prime shipping. The filter is clean. If I wait for a few minutes after that, the pump starts up again at full speed. Then you can pump out the water with a submersible pump, or depending on the surface material and design of your water feature, it may be better for the surfaces not to drain it, but to treat it with chemicals and put a heavy cover over it, where possible. Check for possible turbulence or obstructions inside of the flow T. Ensure there are at least 12 inches of straight pipe before the flow switch. Thanks. Or the filter cartridge may need to be replaced, and is clogged with minerals/dirt/oil, and creating the high pressure itself. Chlorinator Pro CP-15 Cell. pull the water through. Scrape out the old gasket with a sharp screwdriver and glue a new one in place with dabs of superglue gasket flat side down, ridged side up. Any suggestions? Also check that the water level is high enough, and that a skimmer weir is not stuck in the up position, blocking water flow. Hi, open up the air bleeder on the filter when you open the pump to release the vacuum seal from pump to filter. The best way to attack this is with the mantra the problem lies where the power dies. (or 110V, if wired 120V). When I take the lid off the pump hopper I can hear the air releasing, and there cant be any air leaks anywhere as its a new line right from the pump directly into the pool. But not likely, since its been there for years. Hmmm, now if the breaker were stopping the power from flowing to the switch, the timeclock would lose time, and would not turn itself on. Please consider. Most Common areas include the pump lid (must be very tight, with lubed lid o-ring), and the threaded pipe that comes into the FRONT of the pump (must be very tight and sealed if loose, use Pool Putty to fix, or replace the fitting) the effluent or exit pipe fitting leaking will not draw air, that is on the pressure side not the suction side. I have it set on a timer and when the pump comes on the flow rate is good but as the day goes on it becomes less and less. Too bad Hayward doesnt make this more clear on their installation instructions and labeling. And that the top gasket seats well into the groove in the filter body before putting the lid on. The switch or voltage selector, I believe it should be only over one tab, but check the owners manual, or the wiring diagram on the motor. No reset on the pump motor, but a little water on the wiring, and it will pop a GFI outlet. Should I worry? With your timeclock or switch turned on, you should see about 220V, give or take 10%. All breakers are good. Usually its 4 bolts or its a clamp band that connects the seal plate to the volute or strainer housing. It could also be an obstruction in the exhaust, like a birds nest in there, blocking the air flow from the fan. Heaters often normally make such sounds, could also be debris laying on top of the burners. Damaged or inadequate wiring, resulting in a power drop, are likely to blame for your Hayward pool pump shutting off. Also, using Teflon pool lube on the pump lid oring should help. I found the switch to turn off the capacitor was not operating correctly. Hi, I have 2 issues with my 1530 above pool. The only thing I can think of now is a bad breaker box which is outside adjacent to the pump, it is 20 years old. I would recommend getting a plug-in timeclock so you dont need to plug/unplug it all the time. Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. We would like to show you a description here but the site wont allow us. Do you know what the problem is? Probably not your pump basket being full causing this but improper air flow caused by debris/dust. With a test meter, you check power at the motor, and it should be within 10% of 120V or 240V, whichever the motor is wired for, and if not, the power is traced back to a point where it full power is found, on the meter. OR actually, since you say that it starts good and then loses flow that would be different probably an air leak in front of the pump (pump lid, or the pipe coming into the pump, or leaky suction side valve), or a stuck skimmer weir blocking water flow, or low water level causing a vortex in the skimmer. Please contact me at mbrad39972@hotmail.com. 3. inspect clock and rear of motor for any obvious signs of damage, like watermarks, dirt, insects or something burned or melted Same thing if I try to backwash. Problem is now the pool will not clean up (algae) and the pump is slow to prime. I set up to measure motor current, using 100amp, 100mv shunt, the current draw is 6.5 amps @241V (Pump pressure about 17-18 psi) I purchased a SP1580X15 Hayward pump July 2016 and began using it this year 2017. I went with the T3 because It was a significant cost saving and didnt think I would need one for larger pool. I inspected the impeller and it looks fine except where the threads are there are tiny hairline fractions. Remove the 6 bolts that hold the seal plate to the pump housing So, that leads me to the hose having splits, and drawing air in from a few small slits or holes in the hose, or else the hose is crimping due to the strong suction of the pump. I would call back the electrician, he may have fumbled this while wiring it, such a problem is rare, and could hardly be blamed on the manufacturer, but if your electrician says that its not his fault, have him put in writing on company letterhead, what the defect of the motor is which can help you in getting warranty assistance. The help at the pool store had no idea what could be wrong. Below is a list of common issues that can arise with your Hayward pool heater. The motor spins CCW? What do I need to do to fix this? Armstrong Human Resource Management 13th Edition Pdf, Same with other sensors. Hi I have a variable speed ecostar and am now having the drive error, drive stalled. "caption": "In The Swim Blog"
Is this normal or is there a malfunction? Use a flashlight, and you should see gears moving thru the small view hole. The problem lies where the power dies!